Add to Cart
Model | Active Area ft2(m2) | Feed Spacer Thickness(mil) | Permeate Flow Rate GPD(m3/D) | Stabilized Salt Rejection (%) |
XLP-8040 | 440(40.9) | 28 | 11000(41.6) | 99.20 |
XLP-8040HF | 440(40.9) | 28 | 13000(49.2) | 99.00 |
Standard Test Conditions
Solution | Temperature (℃) | pH | Operating Pressure psi(MPa) | Recovery (%) |
500mg/L NaCl | 25 | 7.5-8.0 | 100(0.69) | 15 |
Individual flow rate may vary±15%
Element Dimensions and Operating Limits
Model | Length | Diameter | Permeate Tube inner Diameter | Permeate Tube Extension Length | ||||
inch | mm | inch | mm | inch | mm | inch | mm | |
8040 | 40 | 1016 | 7.9 | 201 | 1.12 | 28.5 | / | / |
4040 | 40 | 1016 | 3.9 | 99 | 0.75 | 19.1 | 1.04 | 26.5 |
Maximum Operating Pressure | 600psi(4.14MPa) |
Operating Temperature Range | 0-45℃ |
Maximum Feed Silt Density Index (SDI15) | 5.0 |
Free Chlorine Tolerance | 0.1mg/L |
pH Range,Continuous Operation | 3-10 |
pH Range,Short-Term Cleaning | 1-13 |
Maximum Element Pressure Drop | 15psi(0.1MPa) |